[version]
ClassGUID
{4D36E97B-E325-11CE-BFC1-08002BE10318}
DriverVer
04/03/2012,5.2.122.0
[Manufacturer]
%LSI%
LSI, NTx86, NTamd64
%DELL%
DELL, NTx86, NTamd64
[SourceDisksNames]
[SourceDisksFiles]
[DestinationDirs]
[ControlFlags]
[Install_INT.NT]
[Install_INT.NT.HW]
Needs
PciIoSpaceNotRequired
[Install_INT.NT.Services]
AddService
megasas, %SPSVCINST_ASSOCSERVICE%, Driver_Install, EventLog_Install
[Install_MSI.NT]
[Install_MSI.NT.HW]
Needs
PciIoSpaceNotRequired
[Install_AddReg_HW]
HKR, Interrupt Management\MessageSignaledInterruptProperties, MSISupported, %REG_DWORD%, %MSI_ENABLED%
HKR, Interrupt Management\MessageSignaledInterruptProperties, MessageNumberLimit, %REG_DWORD%, %MSI_MESSAGES%
HKR, Interrupt Management\Affinity Policy, DevicePolicy, %REG_DWORD%, %AcrossAllProcessors%
HKR, Interrupt Management\Affinity Policy, DevicePriority, %REG_DWORD%, %IrqPriorityHigh%
HKR, Interrupt Management\Affinity Policy, GroupPolicy, %REG_DWORD%, 1
[Install_MSI.NT.Services]
AddService
megasas, %SPSVCINST_ASSOCSERVICE%, Driver_Install, EventLog_Install
[Driver_Install]
ServiceType
%SERVICE_KERNEL_DRIVER%
StartType
%SERVICE_BOOT_START%
ErrorControl
%SERVICE_ERROR_NORMAL%
ServiceBinary
%12%\megasas.sys
LoadOrderGroup
SCSI Miniport
[Parms_AddReg]
HKR, "Parameters", %BUSTYPE_NAME%, %REG_DWORD%, %BUSTYPE_RAID%
HKR, "Parameters\PnpInterface", %PCIBUS%, %REG_DWORD%, 1
HKLM, "System\CurrentControlSet\Services\Disk", %TIMEOUT_VALUE%, %REG_DWORD%, %TIMEOUT_SECONDS%
[EventLog_Install]
[EventLog_AddReg]
HKR,,EventMessageFile, %REG_EXPAND_SZ%, %%SystemRoot%%\System32\IoLogMsg.dll
HKR,,TypesSupported, %REG_DWORD%, 7
[LSI]
[LSI.NTx86]
%mraidsasGeneric.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0409
%mraidsasGeneric.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0411
%mraidsasGeneric.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0413
%mraidsasGeneric.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0060
%mraidsasGenericROMB.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0071
%mraidsasGeneric.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073
%mraidsasGeneric.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0078
%mraidsasGeneric.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079
%mraidsasGeneric.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B
%mraidsasGeneric.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005D
[LSI.NTamd64]
%mraidsasGeneric.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0409
%mraidsasGeneric.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0411
%mraidsasGeneric.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0413
%mraidsasGeneric.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0060
%mraidsasGenericROMB.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0071
%mraidsasGeneric.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073
%mraidsasGeneric.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0078
%mraidsasGeneric.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079
%mraidsasGeneric.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B
%mraidsasGeneric.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005D
[DELL]
[DELL.NTx86]
%perc5E.DeviceDesc%
Install_INT, PCI\VEN_1028&DEV_0015&SUBSYS_1F011028
%perc5I.DeviceDesc%
Install_INT, PCI\VEN_1028&DEV_0015&SUBSYS_1F021028
%perc5in.DeviceDesc%
Install_INT, PCI\VEN_1028&DEV_0015&SUBSYS_1F031028
%perc6E.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0060&SUBSYS_1F0A1028
%perc6i.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0060&SUBSYS_1F0B1028
%perc6int.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0060&SUBSYS_1F0C1028
%perc6int.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0060&SUBSYS_1F0D1028
%cerc6i.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0060&SUBSYS_1F111028
%PERCH700.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F191028
%PERCH700Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F161028
%PERCH700Int.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F171028
%PERCH700Mod.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F181028
%PERCH800.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F1B1028
%PERCH800Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F151028
%PERCH800PAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F1A1028
%PERCH310Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F4E1028
%PERCH310Int.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F4F1028
%PERCH310Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F501028
%PERCH310Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F511028
%PERCH310Embd.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F521028
%PERCH310Embd.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F531028
%PERCH310.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F541028
%PERCH710Embd.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F301028
%PERCH710PAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F311028
%PERCH710PInt.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F321028
%PERCH710PMini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F331028
%PERCH710PMini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F341028
%PERCH710Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F351028
%PERCH710Int.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F361028
%PERCH710Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F371028
%PERCH710Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F381028
%PERCH810Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F2D1028
[DELL.NTamd64]
%perc5E.DeviceDesc%
Install_INT, PCI\VEN_1028&DEV_0015&SUBSYS_1F011028
%perc5I.DeviceDesc%
Install_INT, PCI\VEN_1028&DEV_0015&SUBSYS_1F021028
%perc5in.DeviceDesc%
Install_INT, PCI\VEN_1028&DEV_0015&SUBSYS_1F031028
%perc6E.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0060&SUBSYS_1F0A1028
%perc6i.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0060&SUBSYS_1F0B1028
%perc6int.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0060&SUBSYS_1F0C1028
%perc6int.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0060&SUBSYS_1F0D1028
%cerc6i.DeviceDesc%
Install_INT, PCI\VEN_1000&DEV_0060&SUBSYS_1F111028
%PERCH700.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F191028
%PERCH700Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F161028
%PERCH700Int.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F171028
%PERCH700Mod.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F181028
%PERCH800.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F1B1028
%PERCH800Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F151028
%PERCH800PAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F1A1028
%PERCH310Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F4E1028
%PERCH310Int.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F4F1028
%PERCH310Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F501028
%PERCH310Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F511028
%PERCH310Embd.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F521028
%PERCH310Embd.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F531028
%PERCH310.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F541028
%PERCH710Embd.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F301028
%PERCH710PAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F311028
%PERCH710PInt.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F321028
%PERCH710PMini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F331028
%PERCH710PMini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F341028
%PERCH710Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F351028
%PERCH710Int.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F361028
%PERCH710Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F371028
%PERCH710Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F381028
%PERCH810Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F2D1028
[Strings]
mraidsasGeneric.DeviceDesc
"LSI MegaRAID SAS Adapter"
mraidsasGenericROMB.DeviceDesc
"LSI MegaRAID SAS PCI Express ROMB"
perc5E.DeviceDesc
"DELL PERC 5/E Adapter"
perc5I.DeviceDesc
"DELL PERC 5/i Adapter"
perc5in.DeviceDesc
"DELL PERC 5/i Integrated"
perc6E.DeviceDesc
"DELL PERC 6/E Adapter"
perc6i.DeviceDesc
"DELL PERC 6/i Adapter"
perc6int.DeviceDesc
"DELL PERC 6/i Integrated"
cerc6i.DeviceDesc
"DELL CERC 6/i Integrated"
PERCH310.DeviceDesc
"PERC H310"
PERCH310Adp.DeviceDesc
"PERC H310 Adapter"
PERCH310Int.DeviceDesc
"PERC H310 Integrated"
PERCH310Mini.DeviceDesc
"PERC H310 Mini"
PERCH310Embd.DeviceDesc
"PERC H310 Embedded"
PERCH700.DeviceDesc
"PERC H700"
PERCH700Adp.DeviceDesc
"PERC H700 Adapter"
PERCH700Int.DeviceDesc
"PERC H700 Integrated"
PERCH700Mod.DeviceDesc
"PERC H700 Modular"
PERCH710Adp.DeviceDesc
"PERC H710 Adapter"
PERCH710Int.DeviceDesc
"PERC H710 Integrated"
PERCH710Mini.DeviceDesc
"PERC H710 Mini"
PERCH710Embd.DeviceDesc
"PERC H710 Embedded"
PERCH710PAdp.DeviceDesc
"PERC H710P Adapter"
PERCH710PInt.DeviceDesc
"PERC H710P Integrated"
PERCH710PMini.DeviceDesc
"PERC H710P Mini"
PERCH800.DeviceDesc
"PERC H800"
PERCH800Adp.DeviceDesc
"PERC H800 Adapter"
PERCH800PAdp.DeviceDesc
"PERC H800 Proto Adapter"
PERCH810Adp.DeviceDesc
"PERC H810 Adapter"
SPSVCINST_ASSOCSERVICE
0x00000002
TIMEOUT_VALUE
"TimeoutValue"