[version]
ClassGUID
{4D36E97B-E325-11CE-BFC1-08002BE10318}
DriverVer
3/15/2016,6.805.03.00
[Manufacturer]
%DELL%
DELL, NTx86, NTamd64
[SourceDisksNames]
[SourceDisksFiles]
[DestinationDirs]
[ControlFlags]
[Install_MSI.NT]
[Install_MSI.NT.HW]
Needs
PciIoSpaceNotRequired
[Install_AddReg_HW]
HKR, "Interrupt Management\MessageSignaledInterruptProperties", MSISupported, %REG_DWORD%, %MSI_ENABLED%
HKR, "Interrupt Management\MessageSignaledInterruptProperties", MessageNumberLimit, %REG_DWORD%, 16
HKR, "Interrupt Management\Affinity Policy", DevicePriority, %REG_DWORD%, %IrqPriorityHigh%
HKR, "Interrupt Management\Affinity Policy", DevicePolicy, %REG_DWORD%, %AcrossAllProcessors%
HKR, "Interrupt Management\Affinity Policy", GroupPolicy, %REG_DWORD%, 1
[Install_MSI.NT.Services]
AddService
percsas2i, %SPSVCINST_ASSOCSERVICE%, Driver_Install, EventLog_Install
[Driver_Install]
ServiceType
%SERVICE_KERNEL_DRIVER%
StartType
%SERVICE_BOOT_START%
ErrorControl
%SERVICE_ERROR_NORMAL%
ServiceBinary
%12%\percsas2i.sys
LoadOrderGroup
SCSI Miniport
[Parms_AddReg]
HKR, "Parameters", %BUSTYPE_NAME%, %REG_DWORD%, %BUSTYPE_RAID%
HKR, "Parameters\PnpInterface", %PCIBUS%, %REG_DWORD%, 1
HKR, "Parameters\Device", DriverParameter, 0x00000000, "nonuma
1"
HKR, "Parameters\Device", %512eKey%, %REG_DWORD%, %ENABLED%
HKR, "Parameters", %TIMEOUT_VALUE%, %REG_DWORD%, %TIMEOUT_SECONDS%
[EventLog_Install]
[EventLog_AddReg]
HKR,,EventMessageFile, %REG_EXPAND_SZ%, %%SystemRoot%%\System32\IoLogMsg.dll
HKR,,TypesSupported, %REG_DWORD%, 7
[DELL]
[DELL.NTx86]
%PERCH700.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F191028
%PERCH700Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F161028
%PERCH700Int.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F171028
%PERCH700Mod.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F181028
%PERCH800.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F1B1028
%PERCH800Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F151028
%PERCH800PAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F1A1028
%PERCH310Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F4E1028
%PERCH310Int.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F4F1028
%PERCH310Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F501028
%PERCH310Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F511028
%PERCH310Embd.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F521028
%PERCH310Embd.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F531028
%PERCH310.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F541028
%PERCH310WSAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F781028
%PERCH710Embd.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F301028
%PERCH710PAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F311028
%PERCH710PInt.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F321028
%PERCH710PMini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F331028
%PERCH710PMini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F341028
%PERCH710Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F351028
%PERCH710Int.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F361028
%PERCH710Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F371028
%PERCH710Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F381028
%PERCH810Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F2D1028
%PERCH710PWSAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F771028
%PERCH810V.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F391028
%PERCH810VRes.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F3A1028
%PERCH710VAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F3B1028
%PERCH710PVAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F3C1028
%PERCH710VMini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F3D1028
%PERCH710PVMini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F3E1028
%PERCH710VRes.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F3F1028
%PERCH710PVRes.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F401028
[DELL.NTamd64]
%PERCH700.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F191028
%PERCH700Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F161028
%PERCH700Int.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F171028
%PERCH700Mod.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F181028
%PERCH800.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F1B1028
%PERCH800Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F151028
%PERCH800PAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0079&SUBSYS_1F1A1028
%PERCH310Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F4E1028
%PERCH310Int.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F4F1028
%PERCH310Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F501028
%PERCH310Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F511028
%PERCH310Embd.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F521028
%PERCH310Embd.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F531028
%PERCH310.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F541028
%PERCH310WSAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_0073&SUBSYS_1F781028
%PERCH710Embd.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F301028
%PERCH710PAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F311028
%PERCH710PInt.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F321028
%PERCH710PMini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F331028
%PERCH710PMini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F341028
%PERCH710Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F351028
%PERCH710Int.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F361028
%PERCH710Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F371028
%PERCH710Mini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F381028
%PERCH810Adp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F2D1028
%PERCH710PWSAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_005B&SUBSYS_1F771028
%PERCH810V.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F391028
%PERCH810VRes.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F3A1028
%PERCH710VAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F3B1028
%PERCH710PVAdp.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F3C1028
%PERCH710VMini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F3D1028
%PERCH710PVMini.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F3E1028
%PERCH710VRes.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F3F1028
%PERCH710PVRes.DeviceDesc%
Install_MSI, PCI\VEN_1000&DEV_002F&SUBSYS_1F401028
[Strings]
DISK
"DELL PERC RAID Driver"
PERCH310.DeviceDesc
"PERC H310"
PERCH310Adp.DeviceDesc
"PERC H310 Adapter"
PERCH310Int.DeviceDesc
"PERC H310 Integrated"
PERCH310Mini.DeviceDesc
"PERC H310 Mini"
PERCH310Embd.DeviceDesc
"PERC H310 Embedded"
PERCH700.DeviceDesc
"PERC H700"
PERCH700Adp.DeviceDesc
"PERC H700 Adapter"
PERCH700Int.DeviceDesc
"PERC H700 Integrated"
PERCH700Mod.DeviceDesc
"PERC H700 Modular"
PERCH710Adp.DeviceDesc
"PERC H710 Adapter"
PERCH710Int.DeviceDesc
"PERC H710 Integrated"
PERCH710Mini.DeviceDesc
"PERC H710 Mini"
PERCH710Embd.DeviceDesc
"PERC H710 Embedded"
PERCH710PAdp.DeviceDesc
"PERC H710P Adapter"
PERCH710PInt.DeviceDesc
"PERC H710P Integrated"
PERCH710PMini.DeviceDesc
"PERC H710P Mini"
PERCH800.DeviceDesc
"PERC H800"
PERCH800Adp.DeviceDesc
"PERC H800 Adapter"
PERCH800PAdp.DeviceDesc
"PERC H800 Proto Adapter"
PERCH810Adp.DeviceDesc
"PERC H810 Adapter"
PERCH810V.DeviceDesc
"Shared PERC8 External"
PERCH810VRes.DeviceDesc
"PERC H810V"
PERCH710VAdp.DeviceDesc
"PERC H710V Adapter"
PERCH710PVAdp.DeviceDesc
"PERC H710PV Adapter"
PERCH710VMini.DeviceDesc
"PERC H710V Mini"
PERCH710PVMini.DeviceDesc
"Shared PERC 8"
PERCH710VRes.DeviceDesc
"PERC H710V"
PERCH710PVRes.DeviceDesc
"PERC H710PV"
PERCH310WSAdp.DeviceDesc
"PERC H310 for Dell Precision"
PERCH710PWSAdp.DeviceDesc
"PERC H710P for Dell Precision"
SPSVCINST_ASSOCSERVICE
0x00000002
TIMEOUT_VALUE
"IoTimeoutValue"
512eKey
"EnableQueryAccessAlignment"